Report Slave ID Rollout (response)

This rollout is used to configure Report Slave ID function response parameters. It consists of Run Indicator Status field, Slave ID field, Additional Data field. The Slave ID and Additional Data are variable length fields (device specific). Below are the steps you need to perform to configure the Get Comm Event Log function response parameters properly.

  1. Enter run indicator status value into Run Indicator Status field. It can be a number from 0 to 255. Enter 0 (0x00) for FALSE and 255 (0xFF) for TRUE.
  2. Enter slave ID data (variable length data) into the Slave ID field. You can enter maximum 16 bytes in this field.
  3. Enter additional data (variable length data) into the Additional Data edit box. You can enter maximum 230 bytes in this field.